IECM 12.0 beta User Manual
IECM 12.0 beta User Manual

 

The Air Separation Config parameter screen allows you to configure the chemical looping system's air separation unit. The following parameters are available:

Oxidant (Ox) Composition:

Oxygen (O2): This is the percent of oxygen that is in the oxidant that is produced by the air separation unit.

Argon (Ar): This is the percent of argon that is in the oxidant that is produced by the air separation unit.

Nitrogen (N2): This is the percent of nitrogen that is in the oxidant that is produced by the air separation unit.

Final Oxidant Pressure: The final oxidant stream from the ASU can be provided at a high pressure. The default value is determined by the plant type being used.

Maximum Train Capacity: The maximum production rate of oxidant is specified here. It is used to determine the number of operating trains required.

Number of Operating Trains: This is the total number of operating trains. It is used primarily to calculate capital costs. The value must be an integer.

Number of Spare Trains: This is the total number of spare trains. It is used primarily to calculate capital costs. The value must be an integer.

ASU Power for Calciner Heating: This is the electric power use of ASU that is employed to generate pure O2 for burning to generate heat required for calciner.


Copyright © 2023-2024 University of Wyoming. All rights reserved. Visit us at https://www.iecm-online.com/