IECM 12.0 beta User Manual > Modules Included with the IECM > Pulverized Coal (PC) Plant > SET PARAMETERS > CO2 Capture, Transport & Storage > 1. Chemical Looping > Air Separation Config |
|
The Air Separation Config parameter screen allows you to configure the chemical looping system's air separation unit. The following parameters are available:
•Oxidant (Ox) Composition:
•Oxygen (O2): This is the percent of oxygen that is in the oxidant that is produced by the air separation unit.
•Argon (Ar): This is the percent of argon that is in the oxidant that is produced by the air separation unit.
•Nitrogen (N2): This is the percent of nitrogen that is in the oxidant that is produced by the air separation unit.
•Final Oxidant Pressure: The final oxidant stream from the ASU can be provided at a high pressure. The default value is determined by the plant type being used.
•Maximum Train Capacity: The maximum production rate of oxidant is specified here. It is used to determine the number of operating trains required.
•Number of Operating Trains: This is the total number of operating trains. It is used primarily to calculate capital costs. The value must be an integer.
•Number of Spare Trains: This is the total number of spare trains. It is used primarily to calculate capital costs. The value must be an integer.
•ASU Power for Calciner Heating: This is the electric power use of ASU that is employed to generate pure O2 for burning to generate heat required for calciner.
Copyright © 2023-2024 University of Wyoming. All rights reserved. Visit us at https://www.iecm-online.com/