IECM 12.0 beta User Manual
IECM 12.0 beta User Manual

 

Inputs for the performance of the chemical looping system's carbonator are entered on the Carbonator parameter screen. The following parameters are provided:

Carbonator Temperature: This is the carbonator reactor temperature.

Degree of Carbonation: This is the ratio of the loading difference in the carbonator to the maximum loading difference.

Makeup Limestone/Recirculating Sorbent: This is the ratio of makeup sorbent to recirculating sorbent.

Maximum CaO Conversion: This is the maximum possible fraction of CaO converted to CaCO3 in the carbonator.

Actual CaO Conversion: This is the actual fraction of CaO converted to CaCO3 in the carbonator.

Residence Time of Solids: This is the residence time of solids in the carbonator.

Gas Phase Pressure Drop: This is the pressure drop of flue gas in the carbonator. The flue gas has to be pressurized to overcome this pressure drop, so as to maintain the gas-flow in the CO2 removal system.

ID Fan Efficiency: This is the efficiency of the fan used to raise the flue gas pressure.

Makeup Sorbent Temperature: This is the temperature of the makeup sorbent.


Copyright © 2023-2024 University of Wyoming. All rights reserved. Visit us at https://www.iecm-online.com/