Capture parameters for the adsorber in the solid sorbents TSA system are entered on the Capture - Adsorber parameter screen. The following parameters are shown:

Reactor Type: 2-stage Bub. FB is currently the only option.

Adsorber Operating Temperature: This is the operating temperature of the adsorber.

SO2 Sorbent Loading: This is the SO2 sorbent loading.

Rich Sorbent Loading: This is the rich sorbent loading, estimated based on detailed data from CCSI.

Approach to Equilibrium: This is the ratio of rich sorbent loading to rich sorbent loading at equilibrium expressed as a percentage.

Water Vapor Captured: This is the percentage of water vapor captured.

Makeup Sorbent: This is the amount of makeup sorbent required.

Adsorber Heat Transfer Coefficient: This is the heat transfer coefficient of the adsorber.

Pressure Drop in Adsorber: This is the pressure drop in the adsorber.

ID Fan Efficiency: This is the efficiency of the ID fans.

Cold Side Heat Exchanger Heat Transfer Coeff.: This is the heat transfer coefficient of the cold-side heat exchanger.

Cold Side Heat Exchanger Exit Temp*: This is the outlet temperature of the cold-side heat exchanger. The following related values are shown for reference:

*Min: Adsorber Operating Temp.: This is the minimum outlet temperature.

*Max: Regenerator Operating Temp.: This is the maximum outlet temperature.

*Actual Cold Side Heat Exch Exit Temp.: This is the actual outlet temperature of the cold-side heat exchanger. If the value specified above is out of range, it will be adjusted appropriately. This is the value that will be used.