IECM 12.0 beta User Manual
IECM 12.0 beta User Manual

 

This is a standard O&M cost result screen. The Hot-Side SCR system has the following variable cost components:

Catalyst: Replacement catalyst cost per year for the hot-side SCR. This is a function of the Number of Catalyst Layers, the Catalyst Replacement Interval, and the Catalyst Space Velocity performance parameters.

Ammonia: Ammonia reagent cost per year for the hot-side SCR. This is a function of the concentration of NOx in the flue gas and the ammonia mass flow rate.

Water: Cost of water used to wash ammonia that deposits in the air preheater. This is a function of the efficiency and concentration of ammonia removed by wash water performance parameters and the amount of ammonia salts deposited on the air preheater.

Electricity: Cost of electricity consumption of the hot-side SCR. This is a function of the gross plant capacity and the Hot-Side SCR Power Requirement performance parameter.


Copyright © 2023-2024 University of Wyoming. All rights reserved. Visit us at https://www.iecm-online.com/