Inputs for the performance of the steam cycle are entered on the Steam Cycle Performance parameter screen . This screen is available for both the NGCC and IGCC plant types. The following parameters are available:

Heat Recovery Steam Generator:

HRSG Outlet Temperature: This is the desired output temperature from the heat recovery steam generator (HRSG).

Steam Cycle Heat Rate, HHV: This is the steam cycle heat rate for the heat recovery steam generator. In IGCC plants, this is the nominal steam cycle heat rate; the actual heat rate depends on steam generated in the gasifier cooler.

Cooling Water Temperature Rise: (Not shown when an Air Cooled Condenser is used.) This measures the increase in cooling water temperature after the once-through cooling water removes thermal energy from the exhaust steam.

Auxiliary Heat Exchanger Load (% Primary Steam Cycle): The load on the auxiliary con denser or cooler is expressed as a percent of the load on the primary condenser. This parameter determines the amount of recirculating cooling water used to extract heat from the auxiliary condenser or cooler.

Steam Turbine:

Total Steam Turbine Output: This is the net electricity produced by the steam turbine associated with the HRSG (steam cycle). This value cannot be edited. It is provided for reference only.

Power Block Totals:

Power Requirement: This is the electricity for internal use. It is expressed as a percent of the gross plant capacity.