IECM 12.0 beta User Manual > Modules Included with the IECM > Integrated Gasification Combined Cycle (IGCC) Plant > SET PARAMETERS > Sulfur Removal > Sulfinol Sulfur Capture System > Retrofit or Adjustment Factors |
|
See Retrofit or Adjustment Factor Inputs for an explanation of retrofit costs. The Sulfinol sulfur capture system has the following capital cost process areas:
•COS Conversion System - Hydrolyzer: The Hydrolyzer helps to separate the carbon from the sulfur by converting carbonyl sulfide to hydrogen sulfide.
•Sulfur Removal System - Sulfinol: H2S in the syngas is removed through counter-current contact with the solvent. The cost of the Sulfinol section includes the acid gas absorber, syngas knock-out drum, syngas heat exchanger, flash drum, lean solvent cooler, mechanical refrigeration unit, lean/rich solvent heat exchanger, solvent regenerator, regenerator air-cooled overhead condenser, acid gas knock-out drum, regenerator reboiler, and pumps and expanders associated with the Sulfinol process.
•Sulfur Recovery System - Claus: The Claus plant contains a two-stage sulfur furnace, sulfur condensers, and catalysts.
•Tail Gas Treatment - Beavon-Stretford: The capital cost of a Beavon-Stretford unit varies with the volume flow rate of the input gas streams and with the mass flow rate of the sulfur produced. The regression model is based only on the sulfur produced by the Beavon-Stretford process.
Copyright © 2023-2024 University of Wyoming. All rights reserved. Visit us at https://www.iecm-online.com/