IECM 12.0 beta User Manual > Modules Included with the IECM > Pulverized Coal (PC) Plant > GET RESULTS > By-Product Management > Fly Ash Disposal |
|
The Fly Ash Disposal result screen is only shown when particulate control is configured and fly ash is not mixed with FGD wastes or bottom ash:
PC: GET RESULTS: By-Product Management: Fly Ash Disposal
Each result is described briefly below:
•Above the pond: Fly Ash Disposal Inputs: Solids mixed with sluice water are collected in the particulate removal technolo gies and may be transported to the Landfill for treatment. The IECM currently provides no additional treatment or consideration of these substances, and therefore simply reports the quantities entering the technology.
•Wet Fly Ash: Mass flow rate of total fly ash solids on a wet basis.
•Mercury: Mass flow rate of mercury present in the fly ash solids on a wet basis.
•Below the pond: Fly Ash Disposal Totals:
•Wet Total Solids: The sum of the fly ash and FGD solids on a wet basis.
•Total Mercury: Mass flow rate of mercury present in the combined fly ash and FGD solids on a wet basis.