King Air Facility Instruments

Airborne Instrumentation

The King Air Facility and the UW Department of Atmospheric Science maintain a suite of in situ and remote sensing instruments that are available upon request of the NSF UWKA or C-130 aircraft. A suite of base measurements is available on typical flights. Additional specialized instrumentation are available depending on the goals of the research project and configuration of the payload.

 

Next-Gen King Air Model

UWKA Requestable Instrumentation

Instrument Name

Measurement

Wavelength/Range

Resolution

Sample Rate

Atmospheric State and Navigation

Reverse Flow PRT (Model S1088-1)

Air Temperature (Unheated)

 

 

 

Rosemount 102 (102AU1AF)

Air Temperature(Heated)

-100 - 330 °C

 

 

Buck Research 1011C

Dew Point Temperature

-40 - 50 °C

0.01 °C

 

Mensor CPT 6140 & 9000

Static Pressure

551 - 1172 hPa

 

 

Weston (DPM7885)

Static Pressure

600 - 1150 hPa

 

 

Honeywell PPT2 Transducer (HGPPT2)

Static, AOC, Cabin, Pressures

 

 

 

Rosemount 0858 (w/ PPT2)

True Wind, Angle of Attack

 

 

 

Applanix AV 410 (using AIAS)

Vertical/Horizontal Wind Velocities

 

 

 

Applanix AV 410 (v6 w/ IMU-64)

True Heading, Altitude, Latitude, Longitude,
Pitch, Roll

 

0.015 deg
Heading: 0.02 deg

 

ARINC 429 & 717

Aircraft State

 

 

 

remote sensing

Wyoming Cloud LiDAR (WCL)

Zenith & Nadir Cloud LiDAR

Zenith: 355 nm
Nadir: 351 nm

Zenith: 3.75 m
Nadir: 1.5 m

20 Hz (~4.5 m)

Wyoming Cloud Radar (WCR)

Reflectivity, Doppler Velocity, Doppler Spectra

3.16 mm (94.94 GHz)

37.5 m (for 250 ns pulse length)
7.5 - 30 m range sampling

22 Hz (typical, 4-7 m)

Ka-Band Profiling Radar (KPR)

Reflectivity, Doppler Velocity, Doppler Spectra

8.4 mm (35.64 GHz)

30-75 m resolution
15-37.5 m range sampling

5 Hz (typical, 20 m)

clouds and Aerosols

Gerber PVM-100A* LWC, PSA* 3 - 50 µm drops
0.002 - 10 g/m2
0.002 g/m3 1 - 1,000 Hz
response: 0.0002 s
DMT LWC-301 ("King Probe") LWC 5 - 50 µm drops
0.003 - 3 g/m3
0.003 g/m3 1 or 10 Hz
response: 0.04 s
SkyPhysTech Nevzorov LWC / TWC TWC > 10 µm drops
0.01 - 3 g/m3
0.003 g/m3 1 Hz
Rosemount Icing Detector Supercooled Liquid  Water > 0.01 g/m3 0.003 g/m3 1 Hz
response: 1 s
TSI CPC 3010 & Ultrafine 3025A Condensation Particle Counter 3010: 0.10 - 3 µm   3010 response: < 5 sec
DMT CDP-2 Cloud Droplet Scattering 2 - 50 µm 2 µm; 30 bins 1 - 20 Hz
response: 0.05 s
DMT CIP-G Cloud Particle Images (Grayscale) 0.025 - 1.6 mm 25 µm diode
64 elements
1 Hz
DMT UHSAS Aerosol Spectrometer 0.055 - 1 µm 99 standard bins
Log spacing
20 Hz
DMT SP2-XR Single Particle Soot Photometer 100 - 500 nm
50 - 800 nm
   
DMT PCASP-S200 Cavity Aerosol Spectrometer 0.10 - 3 µm 30 standard bins 0.1 - 25 Hz
Handix POPS Optical Particle Spectrometer 0.13 - 3 µm < 32 bins 1 Hz distributions
SPEC 2D-S Optical Array Images 0.01 - 1.28 mm 10 µm diodes
128 elements
1 Hz
SPEC HVPS Precipitation Spectrometer 0.15 - 19.2 mm 150 µm diodes
128 elements
1 Hz
SPEC 3V-CPI* Three-view Cloud Images 0.01 - 2.35 mm 2.3 µm pixels 400 fps max
BMI IsoKinetic (Model 1200) Isokinetic Aerosol Inlet System 0.005 - 10 µm   1 Hz
HIAPER Modular Inlet (HIMIL) Unheated Inlet      

Radiation

Heitronics KT15.85 Pyrometer Surface Temperature -25 - 200 °C 0.25 °C response: 0.03 s
FLIR Vue Pro-Rt Radiometric Temperature 7,500 - 13,500 nm   7.5 - 25 Hz
TBD* UV, Solar, Infrared      

Air Chemistry and Trace Gases

LI-COR LI-7000 CO2, H2O (Closed Path) CO2: 0 - 3k µmol/mol
H2O: 0-70 mmol/mol
0.01 µmol/mol 20 Hz
LI_COR LI-7500 CO2, H2O (Open Path) CO2: 0 - 3k µmol/mol
H2O: 0-60 mmol/mol
0.01 µmol/mol 20 Hz
Aeris Ultra CO, N2O   CO: 200 ppb
N2O: 200 ppt
1 Hz
response: 1 s
Aeris Ultra CH4, C2H6 CH4: 10 ppb - 10k ppm
C2H6: 1ppb - 1k ppm
CH4: < 1 ppb
C2H6: < 500 ppt
1 Hz
response: 1s
MIRO Analytical MGA10-GP CH4, CO, CO2, NH3, NO, NO2
H2O, SO2, O3, OCS
    1 - 10 Hz
Picarro G2401-Mt CO, CO2, CH4, H2O   5 ppbv 20 Hz
response: 1.3-2 s